Buckleys Bathycorrometer

Hand-Held CP Probe for Subsea Corrosion Surveys

Description

The Buckleys BathyCorrometer® Pro is a hand-held instrument for subsea cathodic protection surveys, measuring the structure-to-electrolyte potential. It has a high-visibility backlit LCD that displays the potential as a negative value, and makes contact with the structure through a hardened stainless steel probe tip. It is rated to 350 m.

The display reads 0.001 to −1.999 V on a 3½-digit LCD, with typical accuracy of 0.05 % and instrument calibration accuracy of ±1 mV ±1 count. The reference electrode is silver/silver chloride/seawater, and a full charge gives 50+ hours of operation. Remote monitoring is possible via the Surface Display Unit Pro (option).

The unit weighs 2.5 kg in air and 0.85 kg in water and measures 10 × 27.5 cm. The kit includes the BathyCorrometer Pro, CalChecker Pro with verification lead, 3 K Series reference electrodes, battery charger, 6 probe tips, probe tip spanner, zinc test block, lanyard, seawater test mixture, carrying case, manual and calibration certificate.